From: Acute exposure to wood smoke from incomplete combustion - indications of cytotoxicity
 | Filtered air | Wood smoke | P-value |
---|---|---|---|
Air vs. Wood smoke | |||
CD3+ ×104/ ml | 1.80 | 1.25 | 0.006 |
1.17–1.34 | 0.98–1.75 | ||
CD4+ ×104/ ml | 1.02 | 0.74 | 0.006 |
0.78–1.34 | 0.52–0.98 | ||
CD8+ ×104/ ml | 0.60 | 0.47 | 0.013 |
0.37–0.94 | 0.24–0.75 | ||
CD16+CD56+ ×103/ml | 0.57 | 0.55 | 0.055 |
0.49–1.18 | 0.36–0.64 | ||
CD4+CD25+ ×103/ml | 0.9 | 0.68 | 0.016 |
0.77–1.41 | 0.58–0.97 | ||
CD4+HLADR+ ×103/ ml | 1.44 | 1.16 | 0.023 |
0.96–2.89 | 0.67–1.81 | ||
CD8+HLADR+ ×103/ml | 1.48 | 1.07 | 0.087 |
0.63–1.82 | 0.37–1.68 | ||
CD8+CD314+ ×103/ml | 2.15 | 1.32 | 0.033 |
1.18–3.17 | 0.73–2.56 |