Skip to main content

Table 4 Pulmonary mRNA expression levels in mice, 1, 3 and 28 days post-exposure to 54 μg, 162 μg and 486 μg sanding dust from epoxy and 162 μg CB

From: Epoxy composite dusts with and without carbon nanotubes cause similar pulmonary responses, but differences in liver histology in mice following pulmonary deposition

 

Control

EPOXY-REF

EPOXY-CNT

EPOCYL

CB

1 day

0 μg

54 μg

162 μg

486 μg

54 μg

162 μg

486 μg

54 μg

162 μg

486 μg

162 μg

 Il-6

0.08 ± 0.02

0.31 ± 0.19

1.19 ± 0.31***

2.33 ± 0.53***

1.45 ± 0.87**

2.32 ± 0.97***

1.91 ± 0.50***

0.26 ± 0.10*

2.43 ± 0.09***

1.35 ± 0.35***

0.21 ± 0.07

 Hmox-1

5.26 ± 0.62

5.98 ± 1.5

13.8 ± 3.0

19.2 ± 2.7**

25.6 ± 10.2

28.9 ± 4.9**

17.2 ± 2.6*

6.85 ± 1.7

17.6 ± 3.8

15.6 ± 3.4

6.22 ± 0.89

3 days

           

 Il-6

0.07 ± 0.01

0.11 ± 0.03

0.51 ± 0.11**

0.6 ± 0.18***

0.11 ± 0.03

0.33 ± 0.15

0.90 ± 0.30

0.14 ± 0.07

0.25 ± 0.07

4.00 ± 1.28***

0.29 ± 0.11

 Hmox-1

3.95 ± 0.72

4.07 ± 0.75

5.28 ± 1.3

6.47 ± 1.7

5.41 ± 1.5

9.11 ± 2.5

14.2 ± 5.7

7.32 ± 2.2

7.74 ± 2.6

28.3 ± 7.7

5.84 ± 1.45

28 days

           

 Il-6

0.24 ± 0.05

0.13 ± 0.03

0.21 ± 0.10

0.25 ± 0.08

0.15 ± 0.08

0.14 ± 0.05

0.17 ± 0.07

0.15 ± 0.03

0.11 ± 0.03

0.33 ± 0.11

0.21 ± 0.05

 Hmox-1

4.95 ± 0.72

5.46 ± 1.3

9.33 ± 2.0

7.72 ± 1.3

3.40 ± 0.84

7.00 ± 2.3

7.38 ± 2.5

6.63 ± 1.0

5.70 ± 0.40

12.9 ± 1.04

4.87 ± 1.6

  1. Normalised mRNA expression level of Il-6 and Hmox-1 (Mean ± SEM)
  2. There were no statistically significant differences between the three sanding dusts at the 0.05 level
  3. *p < 0.05 compared to controls, **p < 0.01 compared to controls, ***p < 0.001 compared to controls