Skip to main content

Table 1 Stability of CdTe/ZnS aqQDs in buffer solutions mimicking blood (pH 7.4)

From: Degradation of aqueous synthesized CdTe/ZnS quantum dots in mice: differential blood kinetics and biodistribution of cadmium and tellurium

Time

Maximal emission (nm)

Relative fluorescent unit

Metal concentrations in filtrate (ng/ml)

Molar ratios of metals in filtrate

   

Cd

Te

Zn

Cd:Te

Zn:Cd

Initial time

652

271.0 ± 6.5

ND

ND

ND

ND

ND

15 min

652

270.5 ± 5.8

2.08 ± 0.12

0.81 ± 0.01

1.30 ± 0.01

2.92:1

1.08:1

30 min

652

270.6 ± 7.9

7.20 ± 0.21

2.90 ± 0.02

4.08 ± 0.05

2.82:1

0.98:1

1 h

652

270.0 ± 9.0

7.72 ± 0.48

2.88 ± 0.30

4.82 ± 0.12

3.05:1

1.08:1

6 h

652

144.1 ± 12.8

8.52 ± 0.95

3.36 ± 0.45

5.02 ± 0.38

2.88:1

1.02:1

24 h

652

104.2 ± 11.1

11.90 ± 1.06

4.91 ± 0.36

7.77 ± 1.01

2.75:1

1.13:1

2 d

652

86.2 ± 10.9

12.87 ± 1.24

5.04 ± 0.44

9.08 ± 0.91

2.90:1

1.22:1

3 d

652

55.2 ± 2.6

14.42 ± 1.80

5.63 ± 0.61

10.50 ± 1.08

2.91:1

1.26:1

  1. ND not detectable. All data are represented as the mean ± SD, n = 3.